Title
  • Investigation of a modified electronic portal imaging device for improving dosimetry in radiotherapy
Author
  • Sabet, Mahsheed
Other Contributors
  • University of Newcastle. Faculty of Science and Information Technology, School of Mathematical and Physical Sciences
Published
  • 2012
Physical Description
  • thesis
Subjects
Summary
  • Research Doctorate - Doctor of Philosophy (PhD)
  • In modern radiotherapy treatments such as Intensity Modulated Radiation Therapy (IMRT), megavoltage beams are delivered using plans that usually include sharp dose gradients. Therefore, high resolution dosimetry devices which provide accurate two-dimensional data are required to ensure the correct delivery of radiation fields. There has been growing interest on using Electronic portal imaging devices (EPIDs) for dosimetry applications. A major problem associated with amorphous silicon (a-Si) EPIDs for transit dosimetry is the presence of a phosphor layer, which can introduce large deviations from water-equivalent behaviour due to energy-dependent response and visible light scattering. In the present study, the phosphor scintillator screen and all other layers above it were removed from the structure of a research-dedicated a-Si EPID and were replaced by buildup layers. The modified EPID (to direct detection configuration) was evaluated for dosimetry applications by comparison to ionization chamber in water measurements for 6 and 18 MV treatment beams. The indirect (unmodified) EPID was similarly investigated in transit dosimetry conditions for comparison. The direct EPID with 3 cm solid water buildup showed water-equivalent response in all tested conditions except for very thick phantoms in 6 MV beams which could be easily corrected, while the indirect EPID was sensitive to changes in field size, phantom thickness and off-axis distance. Some of the EPID characteristics which could affect dosimetry measurements (such as dose rate dependence and image lag) were also investigated for both EPID configurations. The direct EPID was tested for absolute dosimetry measurements with slab and anthropomorphic phantoms in a number of clinical IMRT fields by comparison to a two dimensional array of ionization chambers used as reference and the Gamma evaluation (3%, 3 mm criteria) showed that on average 97.9% of points had a Gamma index less than 1. Monte Carlo method was used to simulate the head of a linear accelerator for 6 MV beams (using BEAMnrc) and the direct EPID (using DOSXYZnrc). The models were then used to simulate the same transit dosimetry conditions as used for the measurements. The agreement of the relative measured and simulated image profiles on the central axis were within 3% for square fields with slab phantoms in the beam. For a head and neck phantom in a dynamic IMRT beam, the Gamma evaluation of measured and simulated relative dose images showed 80.3% of points with Gamma index less than 1 (3%, 3 mm criteria). A simple measurement-based correction model was also developed to correct the EPID images and use them for water-equivalent transit dosimetry without the application of any kernels. The model was tested by comparison of the absolute dose images measured by the EPID and a reference two dimensional array of ionization chambers for clinical IMRT fields in transit conditions, and as a result on average 99.5% of points had a Gamma index less than 1 (3%, 3 mm criteria). The only drawback of using the EPID in direct configuration is the poor quality of images compared with the indirect EPID. If direct EPIDs are used as two-dimensional dosimeters mounted on linacs, on-board kilovoltage imaging devices could be used as an alternative for the EPID (as imager) to confirm patient positioning.
Terms of Use
  • Copyright 2012 Mahsheed Sabet
Language
  • Eng
  • eng
Related Resource
  • University of Newcastle Research Higher Degree Thesis
Identifier
  • oai:novaprd.newcastle.edu.au:uon:10089

Get this edition

  • Set up My libraries

    How do I set up "My libraries"?

    In order to set up a list of libraries that you have access to, you must first login or sign up. Then set up a personal list of libraries from your profile page by clicking on your user name at the top right of any screen.

  • All (1)
  • NSW (1)
None of your libraries hold this item.
None of your libraries hold this item.
None of your libraries hold this item.
None of your libraries hold this item.
None of your libraries hold this item.
None of your libraries hold this item.
None of your libraries hold this item.
None of your libraries hold this item.

User activity


e.g. test cricket, Perth (WA), "Parkes, Henry"

Separate different tags with a comma. To include a comma in your tag, surround the tag with double quotes.

Be the first to add a tag for this edition

Be the first to add this to a list

Comments and reviews

What are comments? Add a comment

No user comments or reviews for this version

Add a comment